فروشگاه

  • ZORBAX SB HPLC Column, 75 x 4.6mm, 3.5µm, P/N: 866953-912

    0 out of 5

    ZORBAX 80Å StableBond

    Longest column lifetime and best reproducibility for low pH separations – down to pH 1
    Patented stable column chemistry allows use at high temperature and low pH without degradation
    Six different bonded phases provide broad selectivity – SB-C18, SB-C8, SB-CN, SB-Phenyl, SB-C3, and SB-Aq
    High purity (Type B) silica for good peak shape

    Agilent ZORBAX StableBond columns use patented, unique, nonfunctional silanes with bulky diisobutyl (SB-C18) or diisopropyl (SB-C8, SB-C3, SB-Phenyl, SB-CN, and SB-Aq) side chain groups that sterically protect the key siloxane bond to the silica surface from hydrolytic attack at low pH. StableBond packing materials are not endcapped in order to provide exceptional stability and to maximize lifetime and reproducibility under acidic mobile phase conditions. The high purity, low acidity silica provides excellent peak shape with acidic, basic and neutral compounds making StableBond columns an excellent choice for low pH method development. ZORBAX StableBond columns are compatible with all common mobile phases, including very high aqueous mobile phases.

    مقایسه
  • ZORBAX SB HPLC Column, 75 x 4.6mm, 3.5µm, P/N: 866953-914

    0 out of 5

    ZORBAX 80Å StableBond

    Longest column lifetime and best reproducibility for low pH separations – down to pH 1
    Patented stable column chemistry allows use at high temperature and low pH without degradation
    Six different bonded phases provide broad selectivity – SB-C18, SB-C8, SB-CN, SB-Phenyl, SB-C3, and SB-Aq
    High purity (Type B) silica for good peak shape

    Agilent ZORBAX StableBond columns use patented, unique, nonfunctional silanes with bulky diisobutyl (SB-C18) or diisopropyl (SB-C8, SB-C3, SB-Phenyl, SB-CN, and SB-Aq) side chain groups that sterically protect the key siloxane bond to the silica surface from hydrolytic attack at low pH. StableBond packing materials are not endcapped in order to provide exceptional stability and to maximize lifetime and reproducibility under acidic mobile phase conditions. The high purity, low acidity silica provides excellent peak shape with acidic, basic and neutral compounds making StableBond columns an excellent choice for low pH method development. ZORBAX StableBond columns are compatible with all common mobile phases, including very high aqueous mobile phases.

    مقایسه
  • µBondapak HPLC Column, 150 x 3.9mm, 10.0µm, P/N: WAT086680

    0 out of 5

    Waters makes the only column that contains the µBondapak® C18 packing material. Other column manufacturers claim their products exhibit “µBondapak-like” selectivity. Yet none of them ever passed Waters’ stringent QC batch tests. Since 1973, µBondapak and Bondapak® packing materials have demonstrated year-to-year reproducibility, which is why µBondapak remains among the most frequently referenced column brands.

    مقایسه
  • µBondapak HPLC Column, 150 x 3.9mm, 10.0µm, P/N: WAT086684

    0 out of 5

    Waters makes the only column that contains the µBondapak® C18 packing material. Other column manufacturers claim their products exhibit “µBondapak-like” selectivity. Yet none of them ever passed Waters’ stringent QC batch tests. Since 1973, µBondapak and Bondapak® packing materials have demonstrated year-to-year reproducibility, which is why µBondapak remains among the most frequently referenced column brands.

    مقایسه
  • µBondapak HPLC Column, 150 x 3.9mm, 10.0µm, P/N: WAT086688

    0 out of 5

    Waters makes the only column that contains the µBondapak® C18 packing material. Other column manufacturers claim their products exhibit “µBondapak-like” selectivity. Yet none of them ever passed Waters’ stringent QC batch tests. Since 1973, µBondapak and Bondapak® packing materials have demonstrated year-to-year reproducibility, which is why µBondapak remains among the most frequently referenced column brands.

    مقایسه
  • µBondapak HPLC Column, 150 x 4.6mm, 10.0µm, P/N: WAT044370

    0 out of 5

    Waters makes the only column that contains the µBondapak® C18 packing material. Other column manufacturers claim their products exhibit “µBondapak-like” selectivity. Yet none of them ever passed Waters’ stringent QC batch tests. Since 1973, µBondapak and Bondapak® packing materials have demonstrated year-to-year reproducibility, which is why µBondapak remains among the most frequently referenced column brands.

    مقایسه
  • µBondapak HPLC Column, 300 x 3.9mm, 10.0µm, P/N: WAT027198

    0 out of 5

    Waters makes the only column that contains the µBondapak® C18 packing material. Other column manufacturers claim their products exhibit “µBondapak-like” selectivity. Yet none of them ever passed Waters’ stringent QC batch tests. Since 1973, µBondapak and Bondapak® packing materials have demonstrated year-to-year reproducibility, which is why µBondapak remains among the most frequently referenced column brands.

    مقایسه
  • µBondapak HPLC Column, 300 x 3.9mm, 10.0µm, P/N: WAT027324

    0 out of 5

    Waters makes the only column that contains the µBondapak® C18 packing material. Other column manufacturers claim their products exhibit “µBondapak-like” selectivity. Yet none of them ever passed Waters’ stringent QC batch tests. Since 1973, µBondapak and Bondapak® packing materials have demonstrated year-to-year reproducibility, which is why µBondapak remains among the most frequently referenced column brands.

    مقایسه
  • µBondapak HPLC Column, 300 x 3.9mm, 10.0µm, P/N: WAT084040

    0 out of 5

    Waters makes the only column that contains the µBondapak® C18 packing material. Other column manufacturers claim their products exhibit “µBondapak-like” selectivity. Yet none of them ever passed Waters’ stringent QC batch tests. Since 1973, µBondapak and Bondapak® packing materials have demonstrated year-to-year reproducibility, which is why µBondapak remains among the most frequently referenced column brands.

    مقایسه